Editer brings you a pure dry goods, solar street light solar battery and battery configuration formula:
One: First calculate the current:
Such as: 12V battery system; 30W lamp 2, total 60 watts.
Current = 60W÷12V= 5 A
II: Calculate the battery capacity requirement:
Such as: street lighting time of 9.5 hours per night, the actual full-load lighting for 7 hours (h);
Example one: 1 LED street light
(eg start 100% power at 7:30 pm, drop to 50% power at 11:00 pm, 100% power after 4:00 AM, close at 5:00 AM)
Example 2: 2-way non-LED lights (low pressure sodium lamp, electrodeless lamp, energy-saving lamp, etc.)
(Such as two-way start at 7:30 in the evening, 1 road at 11:00 in the evening, 2 roads in the morning at 4:00, and close at 5:00 in the morning)
Need to meet the lighting needs of continuous rainy days for 5 days. (5 days plus lighting one night before rainy days, totaling 6 days)
Battery = 5A × 7h × (5 + 1) days = 5A × 42h = 210 AH
In addition, in order to prevent the battery from over-charging and over-discharging, the battery is generally charged to about 90%; the remaining 5% to 20% of the discharge.
So 210AH is only about 70%-85% of the true standard in the application. In addition, according to the different load, measure the actual loss, the actual operating current is affected by the constant current source, ballast, line loss, etc., may increase 15%-25% on the basis of 5A.
Three: Calculate the peak demand of the panel (WP):
The cumulative lighting time of the street lights needs to be 7 hours per hour (h);
★: The panel receives an average of 4.5 hours of light (h) per day;
At least relax 20% of the panel's demand for reservations.
WP ÷ 17.4V = (5A × 7h × 120%) ÷ 4.5h
WP÷17.4V = 9.33
WP = 162(W)
★ : The daily illumination time of 4.5h is the sunshine coefficient near the middle and lower reaches of the Yangtze River.
In addition, in the solar street lamp assembly, the line loss, the loss of the controller, and the power consumption of the ballast or the constant current source are different, and the actual application may be about 15%-25%. So 162W is only a theoretical value, according to the actual situation needs to be increased.
The above content is provided by WOSEN. WOSEN is a professional manufacturer and supplier of Led Flood Light, Led Street Light, Led Solar Light, etc. For more information, please visit https://www.wosenled.com/ or contact admin@wosenled.com or WhatsApp +86-13425434349
August 11, 2023
August 11, 2023
Wyślij je do tym dostawcy
August 11, 2023
August 11, 2023
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.
Fill in more information so that we can get in touch with you faster
Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.